Data Center Redundancy: N+1, 2N, 2(N+1) or 3N2 (distributed) (2024)

Maintaining 100 percent uptime should be, and is top priority for every data center. But what is the difference between the various data center architectures? N+1, 2N, 2(N+1) or distributed redundancy, what is the difference and what impact does the architecture choice of your data center provider have?</p?

What does redundancy mean in Data Centers?

When a data center provider shares their facilities’ redundancy, they are referring to the amount of backup power available. If a utility failures occur due to severe weather, equipment failure or power line damage, data centers with more redundant power will be better equipped to avoid costly periods of downtime.

Most data centers have an architecture in place to cut the risk of downtime. There are different levels of redundancy which are often misunderstood or misrepresented. The purpose of this blog is to clarify the various definitions of data center architectures and highlight some of the misunderstandings often seen in data center evaluations.

What is N?

N equals the amount of capacity required to power or cool the data center facility at full IT load. A design of N means the facility was designed only to account for the facility at full load and zero redundancy has been added. If the facility is at full load and there is a component failure or required maintenance, mission critical applications would suffer. N is the same as non-redundant.

N+1 or N+X Data Center Architecture

If N equals the amount needed to run the data center facility N+1 provides minimal reliability by adding a component to support a single failure or requirement of that component. The simple way to look at N+1 is to think of it in term of ordering cakes for an office party. There are 25 people working in your office and you decide to order one more cake than needed (“just in case”). In this example “N” would represent the exact number of cakes you need (25), while the extra cake is the “+1”. You would be showing up to your office with N+1 or 26 cakes.

A data center example: if the total data center load is 1.000kW and each UPS platform can handle 500kW. In this case we need three UPS systems of 500kW (N=1.000kW, N+1=1.500kW). If one UPS is in maintenance mode we can ensure that the data center can deliver 1.000kW of UPS power. In this example we only name a single component, the UPS, but of course this model is also applicable for the generator and cooling infrastructure.

Data Center Redundancy: N+1, 2N, 2(N+1) or 3N2 (distributed) (1)

Design standards follow a rule of thumb of 1 added component for every 4 (max 5) needed. So, if for example (8) cooling units are required, a total of (10) would be accumulated for in a proper N+1 design.

2N or 2(N+1) Data Center Architecture

2N equates to fully redundant data center architecture, mirrored system, so if two UPS(s) are required there would be completely diverse and independent two UPS(s) for resiliency. In this design one can take down an entire leg with zero interruption to the critical IT load.

The redundant components do not need to be of the same make and model, or even of the same capacity, although redundant components with different capacities can increase the load management challenge. Common misrepresentation with 2N is a facility that is running at half load on an N or N+1 design. Just because a facility is currently at half the load designed does not make it 2N.

Back to our ‘cake’ example: If you need to order cakes for an office party, with 25 people you will order 50 cakes in 2 separate boxes. In this example “N” would represent the exact number of cakes you need (25), while the extra 25 cakes make the 2N. You would be showing up to your office with 2N or 50 cakes.

Data Center Redundancy: N+1, 2N, 2(N+1) or 3N2 (distributed) (2)

In above figure blue represent the “A” side and red represent the “B” side. Loads are redundantly and supported by both power feeds.

For the highest reliability, some data centers offer 2(N+1) architectures, which is actually the double amount capacity needed plus an extra capacity or a redundant N+1 system. This level of redundancy can tolerate multiple component failures or can maintain N+1 redundancy with an entire system down.

The downside of 2(N+1) architectures is the high price which needs to be paid. Besides the initial component costs, as well floor space and as well the high operation costs. For better reliability data centers choose for 2N solutions, which provides more flexibility and easier operational management.

Distributed Redundancy Data Center Architecture (3N/2 redundant)

The three-to-make-two or 3N/2 redundant configuration provides nearly 2N reliability with N+1 capital and operating costs, but with added load management challenges.

In below figure the server environment need 1.500kW of power, based on the distributed redundancy architecture. Each UPS can provide 750kW, if UPS C fails, the server environment will be provisioned with power.

Data Center Redundancy: N+1, 2N, 2(N+1) or 3N2 (distributed) (3)

A 4N/3 or 5N/4 architecture is technically possible but may be less reliable than a basic N architecture, simply because such an elaborate architecture has so many components that can fail and several load balancing points. A balanced architecture can tolerate only one failure without overloading the remaining components and an incorrectly load-balanced architecture may tolerate no failures.

Data Center Redundancy Benefits table

Data Center Redundancy: N+1, 2N, 2(N+1) or 3N2 (distributed) (4)

Summary table: benefits and shortcomings of various redundancy configurations, rated from 1-10, with 10 being the best. Reliability during maintenance assumes that a redundant component is down or that part or the entire system is bypassed.

Industry trend: N+1 Power and cooling redundancy is becoming more common

According to Uptime Institute’s operator survey 2018, N+1 architecture designs are becoming more popular, with 51% of operator respondents having N+1 cooling equipment and 41% having N+1 power equipment configurations.

A 2N design includes 100% replication of components/capacity, and so it would require a major failure of components to cause downtime. In a N+1 design a certain risk is taken on the available capacity because extra capacity/component (or sometime two extra components N+2) will cover for a single failure, or perhaps a limited amount more, but there may not be enough spare capacity to cover for a complete failure of the primary equipment. The use of N+1 is usually justifiable because the risk of multiple failures is so low.

N+1 data center architecture area becoming more popular for three reasons:

  • N+1 data center architecture design is cheaper and more energy efficient because the physical infrastructure is lighter and uses less energy;
  • Many colocation companies are under pressure from their (biggest) clients – cloud service providers – to build an N+1 data center infrastructure for costs reasons;
  • N+1 data center architecture designs of a distributed resiliency plan may help organizations to meet operational requirements as well as better than traditional infrastructures.

Data Center Redundancy: N+1, 2N, 2(N+1) or 3N2 (distributed) (5)

The growth of N+1 architecture is an important trend with implications for data center / colocation providers. One finding from the Uptime Institute Operator Survey is that, of those with a 2N architecture, 22% had experienced an outage in last year, rising to 35% in the past three years (for all failures). But those with an N+1 architecture did not fare so well: 33% said they had an outage in the past year, rising to 51% in the past three years. The message is that the cheaper data center architecture (N+1) is currently less resilient – but that distributed resiliency plans based on N+1 architecture could prove equally as resilient as a 2N data center facility at lower costs.

For more information on Data Center Redundancy Architectures such as N+1, 2N, 2(N+1), Distributed Redundancy and the difference between them, as well as, the different Uptime Tier levels, contact our team (sales@datacenter.com) or call us at +31(0)20 2384200.

Article by J. Steman
Data Center Redundancy: N+1, 2N, 2(N+1) or 3N2 (distributed) (2024)

FAQs

Data Center Redundancy: N+1, 2N, 2(N+1) or 3N2 (distributed)? ›

While 3N/2 distributed redundancy may sound more secure than 2N redundancy, it actually has more in common with N+1 redundancy. There are two backup components for every N component, but instead of being dedicated to one site, the components are distributed across three different sites.

What is the difference between n-1 and 2N redundancy? ›

Reliability and Fault Tolerance: N+1 redundancy provides a reliable backup for most of the business. However, the 2N offers a higher level of reliability because the entire data center can still function, even if a system fails completely.

What is 3N-2 redundancy? ›

The three-to-make-two or 3N/2 redundant model refers to a redundancy methodology where additional capacity is based on the load of the system.

What does n-1 mean in redundancy? ›

With an N+1 system, the 'N' still stands for the minimum number of independent modules required for a system to operate. The "1" in this equation refers to the number of additional components that act as an independent backup that allows the system to operate as intended if one of the modules within 'N' fails.

What is the 2N redundancy model? ›

A 2N redundancy model creates a mirror image of the original UPS, cooling system or generator arrangement to provide full fault tolerance.

What are the two types of data redundancy? ›

In digital image compression, three basic data redundancies can be identified and exploited: coding redundancy, interpixel redundancy, and psychovisual redundancy. Data compression is achieved when one or more of these redundancies are reduced or eliminated.

What is 2N +1 high availability? ›

2N+1 correlates to a system with twice the required resources/capacity to function normally plus a backup as an additional redundancy step. These additional backup systems can provide redundancy even if there is an issue with all of the additional capacity.

How is redundancy defined in a data center? ›

The most common redundancy level in data centers is N+1 redundancy. For every N component in a data center, N+1 redundancy means that there is one backup component available. However, this means that if two or more components fail at the same time, the data center would still have downtime.

What is 4 to make 3 distributed redundant? ›

The “four-to-make-three” (4M3) design automatically switches power distribution to the remaining systems — whether due to unplanned downtime or for cases of maintenance and repair — until full power distribution can be restored.

What is a 2N-1 data center? ›

2N represents 100% redundancy, where data centers have an identical backup to their required components. In a data center where N is the number of UPS units, 2N means having twice as many. Some architecture goes even further and provides 2N+1, which equals a complete backup plus another component.

What does n-1 mean for a data center? ›

If N equals the amount of capacity needed to run the facility, N+1 indicates an additional component added to support a single failure or required maintenance on a component. Design standards typically call for 1 extra unit for every 4 needed.

What is the formula for redundancy? ›

Working backwards from the relevant date, you must add all of the following that apply: 1 and a half week's pay for each full year they were aged 41 years or older. 1 week's pay for each full year they were aged 22 or older, but aged under 41. half a week's pay for each full year they were aged under 22.

What are the types of redundancy in distributed systems? ›

In software engineering, redundancy is broadly classified into three types:
  • Information redundancy.
  • Time redundancy.
  • Physical redundancy.

What is the data redundancy rule? ›

The 3-2-1 rule is the guiding principle of data backup and disaster recovery. The rule states that in order to have a reliable, redundant backup and an effective disaster recovery solution, you must have: three copies of your data, on two forms of media, with one copy located offsite.

What is the data redundancy method? ›

Data redundancy offers an extra layer of protection and reinforces the backup by replicating data to an additional system. It's often an advantage when companies incorporate data redundancy into their disaster recovery plans.

What is N2 redundancy? ›

N2 Redundancy is a must-have for larger businesses that rely on several data centers to execute their services. This backup system provides much-needed wiggle room to address major disasters with ease. Related: Single-Phase vs. Three-Phase Power [Ultimate Guide]

What is n-1 redundancy in UPS? ›

An N+1 UPS system uses multiple UPS to provide redundancy and extra capacity. These styles of systems can take up a large footprint. The N+1 system is designed so that a UPS can be taken entirely offline and still provide you backup with the remaining UPS, however, while working on only one UPS you have no redundancy.

What is n 1 generator redundancy? ›

N+1 Type. The N+1 system configuration is for one or more generators that work together to supply power to the IT load. There is simple generator redundancy in that one of the generators can stop functioning or be taken off-line, if the utility power is interrupted.

What is 2N vs n referring to? ›

The total number of chromosomes in diploid cells is described as 2n, which is twice the number of chromosomes in a haploid cell (n).

Top Articles
Latest Posts
Article information

Author: Eusebia Nader

Last Updated:

Views: 5585

Rating: 5 / 5 (60 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Eusebia Nader

Birthday: 1994-11-11

Address: Apt. 721 977 Ebert Meadows, Jereville, GA 73618-6603

Phone: +2316203969400

Job: International Farming Consultant

Hobby: Reading, Photography, Shooting, Singing, Magic, Kayaking, Mushroom hunting

Introduction: My name is Eusebia Nader, I am a encouraging, brainy, lively, nice, famous, healthy, clever person who loves writing and wants to share my knowledge and understanding with you.